Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev cienc méd pinar río ; 12(1)jul. 2008. ilus, tab
Artigo em Espanhol | CUMED | ID: cum-38350

RESUMO

La respuesta cortical del Potencial Somatosensorial del nervio tibial posterior se registra en la mayor parte de los laboratorios utilizando una sola derivación precisándose cada vez más el diseño de nuevos protocolos que abarquen el registro de mayor número de áreas corticales. Esta investigación se propuso diseñar e implementar el registro del Potencial Evocado Somatosensorial con 19 derivaciones del Sistema Internacional 10/20 en el equipo MEDICID-4 lo que permite el mapeo de la respuesta cortical de la P40 del nervio tibial posterior. Inicialmente se buscó el valor del corte a las altas más bajo, que permitiera obtener el registro sin modificar sus características. Para ello se registró el potencial en 10 sujetos sanos con el electromiógrafo NEURONICA-4 utilizando diferentes filtros a las altas frecuencias. Posteriormente se diseñó un protocolo con 19 derivaciones en el electroencefalógrafo MEDICID-4, utilizando un ancho de banda entre 0,5 y 300 Hz. Fue necesario modificar el software TrackWalker para que permitiera una frecuencia de muestreo de 1 kHz y para lograr que las marcas de sincronismo del estimulador externo fueran reconocidas por el software EP Workstation. Los resultados arrojaron que los cortes a las altas inferiores a 300 Hz modificaron marcadamente la latencia del componente P40. Con este corte se logró obtener respuestas sin diferencias significativas (p> 0,05) en latencia, amplitud y frecuencia a la obtenida con el corte a las altas frecuencias más recomendado en la literatura. Se concluyó que con este protocolo diseñado, es posible registrar la respuesta cortical del Potencial Evocado Somatosensorial del nervio tibial posterior en más de una derivación lo que permitirá contribuir a la caracterización del patrón de anormalidad en ciertos estados patológicos...(AU)


The cortical response of the somatosensory potential of the posterior tibial nerve is recordedin the most of laboratories using only one derivation and requiring even more the design ofthe new protocols involving the record with the most cortical areas; the present research triesto design and implement the Somatosensory Evoked Potential with 19 derivations from theInternational System 10/20 in the 4-MEDICID-equipment, allowing a mapping of the corticalresponse in P40 of the posterior tibial nerve. Initially, we look for the lower cutting value inthe high frequencies which allowed the record with any change in the characteristics. For thispurpose the potential in 10 healthy subjects is recorded using the 4- NEURONICA-electromyography, with the application of different filters in high frequencies. Later, aprotocol with 19 derivations is designed in the 4-MEDICI electromyography using a bandweigh between 0,5 and 300 Hz. It was necessary to modify the Trackwalker software forallowing a 1 kHz sample frequency and for obtaining that the synchronization traces of theexternal stimulator were recognized by EP Workstation software. Findings yielded that cutsat high frequencies less than 300 Hz modified significatively the latency of componentP40.With this cut ,responses with no significant differences were obtained ( p>0,05)according to latency, weigh and frequency in comparison to those obtained with the cut athigh frequencies which is more recommended in literature. It is concluded that with thisprotocol is possible to record the cortical response of the somatosensory evoked potential ofthe posterior tibial nerve in more than a derivation, contributing to the characterization ofabnormal pattern in some pathologic conditions...(AU)


Assuntos
Humanos , Masculino , Adulto , Potenciais Somatossensoriais Evocados/fisiologia , Nervo Tibial
2.
Rev. cienc. med. Pinar Rio ; 12(1): 29-41, ene.-jun. 2008.
Artigo em Espanhol | LILACS | ID: lil-739405

RESUMO

La respuesta cortical del Potencial Somatosensorial del nervio tibial posterior se registra en la mayor parte de los laboratorios utilizando una sola derivación precisándose cada vez más el diseño de nuevos protocolos que abarquen el registro de mayor número de áreas corticales. Esta investigación se propuso diseñar e implementar el registro del Potencial Evocado Somatosensorial con 19 derivaciones del Sistema Internacional 10/20 en el equipo MEDICID-4 lo que permite el mapeo de la respuesta cortical de la P40 del nervio tibial posterior. Inicialmente se buscó el valor del corte a las altas más bajo, que permitiera obtener el registro sin modificar sus características. Para ello se registró el potencial en 10 sujetos sanos con el electromiógrafo NEURONICA-4 utilizando diferentes filtros a las altas frecuencias. Posteriormente se diseñó un protocolo con 19 derivaciones en el electroencefalógrafo MEDICID-4, utilizando un ancho de banda entre 0.5 y 300 Hz. Fue necesario modificar el software TrackWalker para que permitiera una frecuencia de muestreo de 1 kHz y para lograr que las marcas de sincronismo del estimulador externo fueran reconocidas por el software EP Workstation. Los resultados arrojaron que los cortes a las altas inferiores a 300 Hz modificaron marcadamente la latencia del componente P40. Con este corte se logró obtener respuestas sin diferencias significativas (p> 0.05) en latencia, amplitud y frecuencia a la obtenida con el corte a las altas frecuencias más recomendado en la literatura. Se concluyó que con este protocolo diseñado, es posible registrar la respuesta cortical del Potencial Evocado Somatosensorial del nervio tibial posterior en más de una derivación lo que permitirá contribuir a la caracterización del patrón de anormalidad en ciertos estados patológicos.


ABSTRACT The cortical response of the somatosensory potential of the posterior tibial nerve is recorded in the most of laboratories using only one derivation and requiring even more the design of the new protocols involving the record with the most cortical areas; the present research tries to design and implement the Somatosensory Evoked Potential with 19 derivations from the International System 10/20 in the 4-MEDICID-equipment, allowing a mapping of the cortical response in P40 of the posterior tibial nerve. Initially, we look for the lower cutting value in the high frequencies which allowed the record with any change in the characteristics. For this purpose the potential in 10 healthy subjects is recorded using the 4- NEURONICA- electromyography, with the application of different filters in high frequencies. Later, a protocol with 19 derivations is designed in the 4-MEDICI electromyography using a band weigh between 0.5 and 300 Hz. It was necessary to modify the Trackwalker software for allowing a 1 kHz sample frequency and for obtaining that the synchronization traces of the external stimulator were recognized by EP Workstation software. Findings yielded that cuts at high frequencies less than 300 Hz modified significatively the latency of component P40.With this cut ,responses with no significant differences were obtained ( p>0.05) according to latency, weigh and frequency in comparison to those obtained with the cut at high frequencies which is more recommended in literature. It is concluded that with this protocol is possible to record the cortical response of the somatosensory evoked potential of the posterior tibial nerve in more than a derivation, contributing to the characterization of abnormal pattern in some pathologic conditions.

3.
Rev cienc méd pinar río ; 10(2)ene. 2007. tab, graf
Artigo em Espanhol | CUMED | ID: cum-33095

RESUMO

La respuesta cortical del Potencial Evocado Somatosensorial del nervio tibial posterior ha mostrado en diferentes investigaciones una gran variabilidad en cuanto a los resultados obtenidos por diferentes autores. Los objetivos de este trabajo fueron evaluar en una muestra de sujetos adultos sanos la distribución topográfica de la respuesta cortical del potencial evocado somatosensorial del nervio tibial posterior empleando un protocolo de registro con 19 derivaciones del Sistema Internacional 10/20 en el equipo MEDICID-4. Se estudiaron 18 sujetos adultos sanos. En todos los sujetos se obtuvo la respuesta cortical P40, manteniéndose los 19 canales de registro, modificándose los filtros a valores entre 0,5 y 300 Hz, y la frecuencia de muestreo se modificó a 1000 Hz. Los resultados muestran una máxima amplitud de la P 40 en línea media. Además, simultáneamente se obtiene dicha respuesta en la propia región centro-parietal ipsilateral, sin existir gran variabilidad intra e interindividuos. De esto se concluye que la estimulación del nervio tibial el pico P40 mostró una distribución cortical centro-parietal tanto en línea media como ipsilateral, con máxima amplitud en esta última, es decir, la P40 se obtuvo paradójicamente con mayor amplitud hacia la misma región del lado estimulado...(AU)


Assuntos
Potenciais Evocados , Nervo Tibial
4.
Rev. cienc. med. Pinar Rio ; 10(3): 1-10, sep.-dic. 2006.
Artigo em Espanhol | LILACS | ID: lil-739543

RESUMO

La respuesta cortical del Potencial Evocado Somatosensorial del nervio tibial posterior ha mostrado en diferentes investigaciones una gran variabilidad en cuanto a los resultados obtenidos por diferentes autores. Los objetivos de este trabajo fueron evaluar en una muestra de sujetos adultos sanos la distribución topográfica de la respuesta cortical del potencial evocado somatosensorial del nervio tibial posterior empleando un protocolo de registro con 19 derivaciones del Sistema Internacional 10/20 en el equipo MEDICID-4. Se estudiaron 18 sujetos adultos sanos. En todos los sujetos se obtuvo la respuesta cortical P40, manteniéndose los 19 canales de registro, modificándose los filtros a valores entre 0.5 y 300 Hz, y la frecuencia de muestreo se modificó a 1000 Hz. Los resultados muestran una máxima amplitud de la P 40 en línea media. Además, simultáneamente se obtiene dicha respuesta en la propia región centro-parietal ipsilateral, sin existir gran variabilidad intra e interindividuos. De esto se concluye que la estimulación del nervio tibial el pico P40 mostró una distribución cortical centro-parietal tanto en línea media como ipsilateral, con máxima amplitud en esta última, es decir, la P40 se obtuvo paradójicamente con mayor amplitud hacia la misma región del lado estimulado.


The cortical response of the somatosensorial evoked potential of the posterior tibial nerve has shown, in different research works, a great variability in terms of the results obtained by different authors. The aims of this paper were to evaluate in a sample of healthy adult individuals the topographical distribution of the cortical response of the somatosensorial evoked potential of the posterior tibial nerve by using a protocol registration with 19 derivations from the International System 10/20 in the MEDICID-4 team. Eighteen adult individuals were studied. In each individual the cortical response was P40, remaining the 19 registration canals, modifying the filter between 0.5 and 300 Hz, and the sampling frequency was modified to 1000 Hz. Results show a maximum amplitude of the P40 in the middle line. In addition, simultaneously, such response is registered in the central parietal ipsilateral region, with no great intraindividual and interindividual variability. As a conclusion, the stimulation of the tibial nerve and peak P40 showed a cortical central parietal distribution in the middle line, as well as ipsilaterally, with maximum amplitude in the latter. P40 was obtained paradoxically with a greater amplitude towards the same region of the stimulated site.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...